Gas Chromatography Mass Spectrometry GC-MS Testing

    • 1,4 Dioxane

      • Name

        1,4 Dioxane

      • Test Type

        Water

      • Method Reference

        522

      • Sample Amount / Container

        3 – 40 ml vials

      • Preservation

        < 6°C

      • Hold Time

        14 days

      • Baltimore

      • Dayville

      • Fayetteville

      • Louisville

      • Marietta

      • Merrillville

      • Maryville

      • Pittston

      • Warrendale

    • 1,4 Dioxane

      • Name

        1,4 Dioxane

      • Test Type

        Water

      • Method Reference

        8260B / 624.1

      • Sample Amount / Container

        3 – 40 ml vials

      • Preservation

        < 6°C

      • Hold Time

        14 days

      • Baltimore

      • Dayville

      • Fayetteville

      • Louisville

      • Marietta

      • Maryville

      • Merrillville

      • Pittston

      • Warrendale

    • Base Neutral (BN) Extractibles

      • Name

        Base Neutral (BN) Extractibles

      • Test Type

        Water

      • Method Reference

        8270C, D,E / 625.1

      • Sample Amount / Container

        2 – 1 L Amber glass

      • Preservation

        < 6°C

      • Hold Time

        7 / 40 days

      • Notes

        Marietta = 2-120mL amber

      • Baltimore

      • Dayville

      • Fayetteville

      • Louisville

      • Marietta

      • Maryville

      • Merrillville

      • Pittston

      • Warrendale

    • Phenols – Acid Extractables

      • Name

        Phenols – Acid Extractables

      • Test Type

        Water

      • Method Reference

        8270C,D, E / 625.1

      • Sample Amount / Container

        2 – 1 L Amber glass

      • Preservation

        < 6°C

      • Hold Time

        7 / 40 days

      • Notes

        Marietta = 2-120mL amber

      • Baltimore

      • Dayville

      • Fayetteville

      • Louisville

      • Marietta

      • Maryville

      • Merrillville

      • Pittston

      • Warrendale

    • PAHs

      • Name

        PAHs

      • Test Type

        Water

      • Method Reference

        8270C,D, E / 625.1

      • Sample Amount / Container

        2 – 1 L Amber glass

      • Preservation

        < 6°C

      • Hold Time

        7 / 40 days

      • Notes

        Marietta = 2-120mL amber

      • Baltimore

      • Dayville

      • Fayetteville

      • Louisville

      • Marietta

      • Maryville

      • Merrillville

      • Pittston

      • Warrendale

    • PAHs (low level)

      • Name

        PAHs (low level)

      • Test Type

        Water

      • Method Reference

        8270C,D, E / 625.1 SIM

      • Sample Amount / Container

        2 – 1 L Amber glass

      • Preservation

        < 6°C

      • Hold Time

        7 / 40 days

      • Notes

        Marietta = 2-120mL amber

      • Baltimore

      • Dayville

      • Fayetteville

      • Louisville

      • Marietta

      • Maryville

      • Merrillville

      • Pittston

      • Warrendale

    • Pentachlorophenol (PCP)

      • Name

        Pentachlorophenol (PCP)

      • Test Type

        Water

      • Method Reference

        8270C,D, E / 625.1 SIM

      • Sample Amount / Container

        2 – 1 L Amber glass

      • Preservation

        < 6°C

      • Hold Time

        7 / 40 days

      • Notes

        Marietta = 2-120mL amber

      • Baltimore

      • Dayville

      • Fayetteville

      • Louisville

      • Marietta

      • Maryville

      • Merrillville

      • Pittston

      • Warrendale

    • SVOC

      • Name

        SVOC

      • Test Type

        Water

      • Method Reference

        525/8270C, D, E / 625.1

      • Sample Amount / Container

        2 – 1 L Amber glass

      • Preservation

        < 6°C

      • Hold Time

        7 / 40 days

      • Notes

        Marietta = 2-120mL amber

      • Baltimore

      • Dayville

      • Fayetteville

      • Louisville

      • Marietta

      • Maryville

      • Merrillville

      • Pittston

      • Warrendale

    • SVOC 625 (waste water)

      • Name

        SVOC 625 (waste water)

      • Test Type

        Water

      • Method Reference

        625.1

      • Sample Amount / Container

        2 – 1 L Amber glass

      • Preservation

        < 6°C

      • Hold Time

        7 / 40 days

      • Notes

        Marietta = 2-120mL amber

      • Baltimore

      • Dayville

      • Fayetteville

      • Louisville

      • Marietta

      • Maryville

      • Merrillville

      • Pittston

      • Warrendale

    • VOCs 524.2 (drinking water)

      • Name

        VOCs 524.2 (drinking water)

      • Test Type

        Water

      • Method Reference

        524.2

      • Sample Amount / Container

        Ascorbic Acid, pH<2, HCL

      • Preservation

        Ascorbic Acid, pH<2, HCL, < 6°C

      • Hold Time

        14 days

      • Baltimore

      • Dayville

      • Fayetteville

      • Louisville

      • Marietta

      • Merrillville

      • Maryville

      • Pittston

      • Warrendale

    • VOCs 624 (waste water)

      • Name

        VOCs 624 (waste water)

      • Test Type

        Water

      • 624.1

      • Method Reference

        3 – 40 ml vials

      • Sample Amount / Container

        < 6°C, Sodium Thiosulfate

      • Preservation

        14 days

      • Baltimore

      • Dayville

      • Fayetteville

      • Louisville

      • Marietta

      • Merrillville

      • Maryville

      • Pittston

      • Warrendale

    • VOCs (medium level)

      • Name

        VOCs (medium level)

      • Test Type

        Water

      • Method Reference

        8260B, C, D

      • Sample Amount / Container

        3 – 40 ml vials

      • Preservation

        < 6°C, pH <2, HCL

      • Hold Time

        14 days

      • Notes

        7 days if unpreserved

      • Baltimore

      • Dayville

      • Fayetteville

      • Louisville

      • Marietta

      • Maryville

      • Merrillville

      • Pittston

      • Warrendale

    • VOCs (low level)

      • Name

        VOCs (low level)

      • Test Type

        Water

      • Method Reference

        8260B, C, D

      • Sample Amount / Container

        3 – 40 ml vials

      • Preservation

        < 6°C, pH <2, HCL

      • Hold Time

        14 days

      • Notes

        7 days if unpreserved

      • Baltimore

      • Dayville

      • Fayetteville

      • Louisville

      • Marietta

      • Maryville

      • Merrillville

      • Pittston

      • Warrendale